How to Add an Auto-Shut-Off (ASO) Valve to RO-Perm System

Parts Included for Conversion: 1 ASO Valve w/ Pre Inserted Tubing, Inserts and Compression Nuts. 1 ASO Clip w/ Screw To add the Auto-Shut-Off valve to the RO-Perm System, please follow steps below:...

View Article



APEC Reverse Osmosis (RO)-45 System Filter Change Instruction

Changing Stages 1, 2, 3 Pre-Filters:  (should be changed at least every 12 months) Turn OFF cold water supply to RO system.  Turn OFF the tank ball valve.  Lift up RO faucet lever briefly to relief...

View Article

APEC Reverse Osmosis (RO) – 90 System Filter Change Instruction

Changing Stages 1, 2, 3 Pre-Filters:  (should be changed at least every 12 months) Turn OFF cold water supply to RO system.  Turn OFF the tank ball valve.  Lift up RO faucet lever briefly to relief...

View Article

APEC Reverse Osmosis (RO) – PERM System Filter Change Instruction

Changing Stages 1, 2, 3 Pre-Filters:  (should be changed at least every 12 months) Turn OFF cold water supply to RO system.  Turn OFF the tank ball valve.  Lift up RO faucet lever briefly to relief...

View Article

APEC Countertop Pre-Filters and Membrane Replacement

Suggested tools:  A pair of scissors, pair of pliers and the membrane wrench  Quick Connect Guide:      Connect Tubing Press Down on collet to Pull out Tubing   Filter Ports:  All filters have...

View Article


How to Flush and Sanitize an APEC Reverse Osmosis (RO) – 45 system

When the RO system and tank are contaminated, they need to be thoroughly flushed and sanitized before putting in new filter cartridges, and restoring the system back to use. Please follow the steps...

View Article

Instructions on How to Insert Membrane

IMPORTANT!  Must Insert Membrane Into This Housing Before Use! Insert Membrane This Direction: Open housing’s cap: Remove the Red tubing from cap first, then open cap. Use pliers to handle membrane...

View Article

Saddle Feed Installation Instructions for 3/8″ Brass adapter

Before connecting your extender tee, close your supply stop and disconnect the water line to the faucet at the supply stop valve. Attach the extender tee to your supply stop and re-connect faucet water...

View Article


APEC RO System: Permeate Pump Replacement

To replace the Permeate Pump on your RO system, please follow steps below: Turn off the feed water to the RO system. Close the tank’s ball valve by turning the blue cap on the tank ball valve 90...

View Article


APEC RO-CTOP System: Faucet Adaptor Kit Replacement

To replace the faucet adaptor on your RO-CTOP system, please follow the instructions below: Remove faucet adaptor:  Unscrew and remove the feed water Faucet Adaptor from your faucet. Remove...

View Article